| Specifications |
OS10 |
| BTU
INPUT: |
From
8,500 to 42,700 |
BTU
OUTPUT:
|
From
6,800 to 34,800 |
| FLUE: |
4"
or 5" ; top vented,
convertible to rear vent |
| VENTING: |
A-Vent,
L-Vent |
| HEIGHT: |
29
1/2" |
| WIDTH: |
24
1/2" |
| DEPTH: |
21" |
| WEIGHT: |
260
lbs |
| OIL
TYPE: |
Furnace
Oil No. 2 or No. 1 |
| CONSUMPTION: |
0.25
litre/hr (0.066 US gal/hr) min to 1.25
litre/hr (0.33 US gal/hr) max |
HEIGHT,
FLOOR TO
CENTRE OF REAR FLUE: |
23" |
| Minimum
Clearances to Cumbustable Surfaces |
| FROM BACK WALL TO
CHIMNEY CONNECTOR: |
12"
(305mm) |
| FROM SIDE WALL TO
SIDE OF
STOVE: |
19" (305mm) |
|
With
this pump you are able to
pump oil from the oil tank to higher
locations throughout your home to a maximum of 23'. This enables you to
locate your oil stove on your first or second floor.
81.5% MAXIMUM
HIGH EFFICIENCY
CERTIFIED IN CANADA TO CAN/CSA 22.2
#B
40.0 - M87 R91 B140.1 AND B140.3 ,br>AND IN THE UNITED STATES TO UL896 |